Wet scrubbing / PFD-07

Venturi scrubber with external reservoir

Combine venturi particulate collection with a separate water reservoir when the site layout calls for an external liquid-handling arrangement.

Process flow diagram

PFD-07 ORIGINAL DRAWINGEnlarge drawing ↗
PFD-07: original Ponka process flow diagram for Venturi scrubber with external reservoir.
Ponka Engineering Alliance · Custom Air Systems Engineering (2018) Full sheet, p. 9 ↗

Reading the drawing

Two exhaust branches feed the wetted venturi, where water contacts the dust. The droplet separator removes entrained liquid before the exhaust fan discharges air to atmosphere. Here the separator drains to a separate reservoir below it. The reservoir receives make-up water, and the pump sends water back to the venturi, with a branch for bleed-off.

Mining applications

Treating process exhaust

This variant separates the recirculation reservoir from the gas-treatment equipment. It gives the project team another way to arrange the scrubber, pump and water-handling access while retaining venturi contact and downstream droplet separation.

Mineral-processing exhaust selected for wet particulate collection.
Retrofits where the reservoir needs a separate equipment location.
Scrubbing duties requiring accessible water-level and bleed-off management.
Typical operating steps for this application
  1. Scrub the particulate stream

    The wetted venturi brings the extracted process air and circulating liquid into contact.

  2. Remove entrained liquid

    The separator drains collected droplets while air continues to the exhaust fan and the designed outlet.

  3. Return water to the reservoir

    Drain piping connects the wet equipment to the external reservoir. Elevations and pressure conditions determine the drainage arrangement.

  4. Supply and renew the loop

    The pump supplies scrubbing water. Level control, make-up and bleed-off manage the liquid inventory and connect to the selected treatment route.

Main components

ComponentRole in the system
Venturi contact section ↗Transfer particulate into the scrubbing liquid.
Droplet separator ↗Remove entrained droplets before the air outlet.
External reservoir and pumpCollect returning liquid and supply the recirculation loop.
Exhaust fan ↗Provide extraction through the wet collection equipment.

Linked components open the VentilationComponents.com supplier catalogue. Equipment selection forms part of the system engineering.

Before equipment selection

What to discuss with Ponka

  • Reservoir location, drainage elevations and access for cleaning.
  • Solids accumulation, water chemistry and a defined bleed-off destination.
  • Pump suction conditions, liquid-flow monitoring and loss-of-flow response.
  • Freeze protection and materials suited to the process liquid.